Back to top
08045802918
Send SMS    Call Me Free Send Inquiry
IC 10-27 Cooling Tower Fill Media
IC 10-27 Cooling Tower Fill Media

IC 10-27 Cooling Tower Fill Media

Price 2800 INR/ Cubic Meter

MOQ : 1 Cubic Meter

IC 10-27 Cooling Tower Fill Media Specification

  • Water in conductivity
  • Depends on Raw Water Quality
  • Water Out Conductivity
  • Depends on Water Quality
  • Warranty
  • As Per Manufacturer's Terms
  • Ph Level
  • As Per Water Quality and Material Compatibility
  • Technology
  • Evaporative Cooling / Heat Transfer
  • Flow Rate
  • As Per Cooling Tower Design (m³/hr)
  • Pump Type
  • Not Applicable (Fill Media Only)
  • Recycle Rate
  • As Per Cooling Tower System Design
  • Usage & Applications
  • Industrial Cooling Towers, HVAC Systems, Power Plants, Chemical Plants, Process Industries
  • Efficiency (%)
  • Depends on Tower Design and Operating Conditions
  • Feature
  • High Heat Transfer Efficiency, Lightweight, Durable, Corrosion Resistant
  • Automatic Grade
  • Other
  • Material
  • PVC
  • Purity Level
  • Industrial Grade
  • Drive Type
  • Other
  • Water Source
  • Other
  • Power Source
  • Not Required
  • Product Type
  • IC 10-27 Cooling Tower Fill Media
  • Filter Type
  • Film Fill Media
  • Installation Type
  • Other
  • Minimum Water Load
  • 3 m3/m2h
  • Material
  • PVC
  • Features
  • Light Weight, Mass transfer and heat transfer coefficient, Fire Resistant
  • Flute Size
  • 27 mm
  • Surfance of Exchange
  • 112 m2/m3
  • Weight
  • 28 Kg/m3
 

IC 10-27 Cooling Tower Fill Media Trade Information

  • Minimum Order Quantity
  • 1 Cubic Meter
  • FOB Port
  • SOB JEBEL ALI PORT U.A.E
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 2000 Cubic Meters Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About IC 10-27 Cooling Tower Fill Media



Discover the latest IC 10-27 Cooling Tower Fill Media, a phenomenal solution engineered from durable, self-extinguishing grade PVC. With a corrugated 27 mm profile and exceptional operating range up to 55C, this drift eliminator fill ensures ultimate heat exchange and cooling efficiency-essential for industrial and commercial cooling towers. Favorable reviews hail its anti-fouling, lightweight construction and over 10-year usage life. Limited stock available-its customizable design fits various tower needs. Exceptional performance, easy cleaning, and reliable durability make it your ultimate cooling solution.

Versatile Usage & Broad Industrial Application

IC 10-27 Cooling Tower Fill Media is expertly designed for enhancing cooling efficiency in a wide range of cooling towers. Perfect for both industrial and commercial applications, it supports major plants such as power generation, chemical processing, and HVAC systems. Its robust PVC construction and corrugated pattern enable effective heat exchange and drift elimination in atmospheric pressure environments, making it a trusted choice across diverse sectors seeking long-term reliability and performance.


Certifications, Export Markets & Order Guidelines

IC 10-27 Cooling Tower Fill Media is backed by rigorous certifications ensuring safety and performance. It is widely exported to international markets, reflecting its global demand and dependability. Sample policies are available to facilitate bulk orders, and seamless transport services ensure timely delivery upon purchase order confirmation. The process from order placement to final order completion is smooth and professional, guaranteeing convenience and client satisfaction at every stage.


FAQ's of IC 10-27 Cooling Tower Fill Media:


Q: How is the IC 10-27 Cooling Tower Fill Media installed?

A: The fill media is supplied in loose blocks or bundles and can be field-assembled onto grid supports or slats within the cooling tower. Its panel/block type design ensures flexible installation for various tower layouts.

Q: What are the main benefits of using this fill media in cooling towers?

A: The primary benefits include superior cooling efficiency, anti-fouling properties, lightweight yet durable construction, a lifespan of over 10 years, and fire-retardant self-extinguishing PVC for enhanced safety.

Q: Where is the IC 10-27 Fill Media best applied?

A: It is best suited for industrial and commercial cooling towers, especially in power plants, chemical facilities, and HVAC systems that require reliable heat exchange and drift elimination.

Q: What is the recommended maintenance and cleaning process?

A: The fill media can be easily cleaned either manually using water jetting or through chemical cleaning, ensuring continued optimal performance and longevity.

Q: When should this product be chosen for cooling tower projects?

A: Choose the IC 10-27 fill media when you need a customizable solution that delivers ultimate efficiency and durability for high-performance cooling tower systems.

Q: What is the expected usage life of the IC 10-27 Cooling Tower Fill Media?

A: When maintained properly, the fill media offers an exceptional usage life exceeding 10 years, ensuring long-term operational reliability.

Technical Details 

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Tube Settler Category

IC 10-19 Structured Film Fill Media

IC 10-19 Structured Film Fill Media

Price 2800 INR / Cubic Meter

Minimum Order Quantity : 1 Cubic Meter

Efficiency (%) : Depends on Cooling Tower Design and Operating Conditions

Capacity : As Per Cooling Tower Design (m/hr)

Filter Type : Structured Film Fill

Feature : High Heat Transfer Efficiency, Lightweight, Durable, Corrosion Resistant

Tube Settler

Tube Settler

Price 5500 INR / Cubic Meter

Minimum Order Quantity : 1 Cubic Meter

Efficiency (%) : Depends on Design and Operating Conditions

Capacity : As Per Plant Design (m/hr) m3/hr

Filter Type : Tube Settler / Lamella Clarifier Media

Feature : High Settling Efficiency, Lightweight, Durable, Corrosion Resistant